Operation Refrigeration air dryer
Refrigeration Compressed Air Dryer
Refrigerated and heatless are two broad categories of air dryers available these days. Talking about air dryers remains incomplete without mentioning the concept of dew point temperature. It is the unit used to measure the dryness of compressed air. At this temperature, the moisture present in the compressed air in vapour form condenses to form liquid. Similarly, pressure dew point temperature and atmospheric dew point temperature are the two distinct temperatures of compressed air when under any kind of pressure and atmospheric pressure respectively. When we talk about the most advanced and cheapest mode of drying compressed air, refrigerated air dryers are quintessential.
Compressed air is normally fully saturated with water vapour. Air dryers are used to remove water vapour from compressed air. Refrigeration dryers are the most energy and correct solution for drying air suitable for Compressed air, which is used in most machines that need a pressure dewpoint in the range between +3° C to +10°C.
Our refrigerated dryers are the perfect solution for preventing condensation and corrosion in your compressed air system. With minimal maintenance required, our dryers deliver maximum uptime. Their innovative design offers reliability, efficiency, and a compact footprint, making them ideal for all industrial applications.
Salient Features
- New Controller with interface for Trident DryLink2 . When this optional accessory is used the dryer can be connected to Factory automation using modbus and Trident Cloud for remote management and analytics
- Large condenser for high ambient temperatures
- All Aluminium Air to Air , Air to freon heatexchanger with in-buillt moisture separator
- Anti-recycle feature for compressor protection
- Low pressure drop across advanced heat exchanger saves energy
- The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007
- Air quality class - ISO 8573 - 1 : 2010 (E) class -5-
Refrigerated air dryer systems and heatless are two broad categories of air dryers available these days. Talking about air dryers remains incomplete without mentioning the concept of dew point temperature. It is the unit used to measure the dryness of compressed air. At this temperature, the moisture present in the compressed air in vapour form condenses to form liquid. Similarly, pressure dew point temperature and atmospheric dew point temperature are the two distinct temperatures of compressed air when under any kind of pressure and atmospheric pressure respectively. When we talk about the most advanced and cheapest mode of drying compressed air, refrigerated air dryers are quintessential.
- Large condenser for high ambient temperatures
- Anti-recycle feature for compressor protection
- Low pressure drop across advanced heat exchangers saves energy
- The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007
- Dryer quality class - ISO 8573 - 1 : 2010 (E) class -5
- New Controller with interface for Trident DryLink2 . When this optional accessory is used the dryer is can be connected to Factory automation using modbus and Trident Cloud for remote management and analytics
- Large condenser for high ambient temperatures
- All Aluminium Air to Air , Air to freon heatexchanger with in-buillt moisture separator
- Anti-recycle feature for compressor protection
- Low pressure drop across advanced heat exchangers saves energy
- The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007
- Dryer quality class - ISO 8573 - 1 : 2010 (E) class -5-
Operation Refrigeration air dryer
The principle on which the Refrigeration air dryer manufacturers takes place and subsequently works is that cooling of compressed air cause condensation of water that is carried by the compressed air in vapour form. The cooling takes place in two stages in the refrigerated type of air dryer. The compressed air enters the refrigerated type of air dryer at about 40 degree Celsius. It enters the pre-cooler firstly wherein the outgoing cool-dry air cools the incoming hot-wet air. The outgoing cool-dry air on the other hand is heated upto an operating temperature of about 28-32 degree Celsius. This partially cooled hot-wet air then enters the evaporator wherein it is chilled down to a temperature of about 2-8 degree Celsius. The chilling down of the hot-wet air condenses the moisture bored by the air in vapour form. Next, the chilled air bearing condensed moisture is subjected into the moisture separator, which is a mechanical equipment that helps separate the condensed moisture from the air by mechanical activity. The moisture separator drains out the moisture via an automatic drain valve. This cool-dry air is then passed through the pre-cooler as mentioned above. In a nutshell, this process produces dry air which can be obtained through the outlet. This dry air is of a pressure dew point temperature of about 4 degree Celsius or as required but above 2 degree Celsius. The amount of power consumed by drying air in the refrigerated air dryers is approximately 5.0 kwh for 1000 cubic feet per minute of air.
What Trident Offers
An ideal solution for clean and compressed dry air is provided by Trident , one of the experts among the Refrigerated air dryer Manufacturers. Extensive design strategies and prototype testing culminates in Trident’s amazing products that offer a constant dew point of +3 degree Celsius. Also, the HX series of Trident offers a very low running cost unlike the other air dryers. Some exclusive features of these products are:-
The cold dry compressed air passes back through the secondary side of the Air to Air heat exchanger where it is reheated by the incoming warm air. Reheating the outgoing compressed air increases the volume of the air enabling it to do more work and it also prevents downstream pipe sweating. Trident heat exchanger has no extended surfaces or sharp corners that collect dust, dirt or oil residue. Their self cleaning smooth surface tube in shell and tube design will maintain the same heat transfer efficiency through out the dryer’s life. Any dust, dirt or oil will be washed off from the air system along with the condensed moisture at the De-mister.
REFRIGERATED AIR DRYER MANUFACTURERS
- Maintaining of a consistent pressure dew point.
- Control of the condensing temperature for atmospheric variations in temperature.
- The safety of compressor provided by the HP cut switch.
- The advanced mimic display that indicates the functions and faults if any.
- The provision of Trident automatic drain valve in Demister and Heat exachangers for efficient dryer functioning.
Product Range
Model | Item Code | Flow in scfm | Power consumption (KW) R134a/R407c |
End connection | Dimension (mm) | Weight (kg) | Recommened Pre Filter** 5 Micron |
Recommened Post Filter** |
|||
---|---|---|---|---|---|---|---|---|---|---|---|
H | W | D | 1 Micron | 0.01 Micron | |||||||
Coldspell 20 | PH277 | 20 | 0.20/— | ½” BSP | 506 | 202 | 502 | 25 | T100PEA | T100XIA | T100YIA |
Coldspell 40 | PH251 | 40 | 0.30/— | ½” BSP | 556 | 252 | 578 | 48 | T100PEA | T100XIA | T100YIA |
Coldspell 60 | PH253 | 60 | 0.30/— | ½” BSP | 556 | 252 | 578 | 48 | T100PEA | T100XIA | T100YIA |
Coldspell 80 | PH283 | 80 | 0.60/— | 1” BSP | 651 | 252 | 602 | 65 | T250PEA | T250XIA | T250YIA |
Coldspell 100 | PH284 | 100 | 0.60/— | 1” BSP | 651 | 252 | 602 | 65 | T250PEA | T250XIA | T250YIA |
Coldspell 150 | PH280 | 150 | 0.90/— | 1½” BSP | 828 | 322 | 986 | 123 | T250PEA | T250XIA | T250YIA |
Coldspell 200 | PH278 | 200 | —/1.50 | 1½” BSP | 828 | 322 | 986 | 129 | T600PEA | T600XIA | T600YIA |
Coldspell 250 | PH279 | 250 | —/1.50 | 1½” BSP | 828 | 322 | 986 | 129 | T600PEA | T600XIA | T600YIA |
Coldspell 300 | PH270 | 300 | —/1.70 | 2” BSP | 1251 | 490 | 1005 | 140 | T600PEA | T600XIA | T600YIA |
Coldspell 400 | PH271 | 400 | —/2.20 | 2” BSP | 1251 | 490 | 1005 | 140 | T851PEA | T851XIA | T851YIA |
Coldspell 525 | PH272 | 525 | —/3.20 | 2” BSP | 1251 | 490 | 1005 | 160 | T851PEA | T851XIA | T851YIA |
Coldspell 650 | PH273 | 650 | —/3.20 | 2” BSP | 1251 | 490 | 1005 | 160 | T1210PEA | T1210XIA | T1210YIA |
Coldspell 800 | PH274 | 800 | —/4.60 | 4” NB | 1305 | 640 | 1355 | 450 | T1810PEA | T1810XIA | T1810YIA |
Coldspell 1000 | PH275 | 1000 | —/5.20 | 4” NB | 1305 | 640 | 1355 | 450 | T1810PEA | T1810XIA | T1810YIA |
Coldspell 1250 | PH276 | 1250 | —/7.10 | 4” NB | 1305 | 640 | 1355 | 450 | T2200PEA | T2200XIA | T2200YIA |
Coldspell 1500 | PH281 | 1500 | —/7.40 | 4” NB | 1460 | 1025 | 1115 | 550 | T2600PEA | T2600XIA | T2600YIA |
Coldspell 2000 | PH282 | 2000 | —/8.60 | 6” NB | 1460 | 1025 | 1115 | 550 | T3400PEA | T3400XIA | T3400YIA |
* 11/2022