Medical Vaccuum filters
High performance series

A leading manufacturer since 1988

Medical filter

Medical Breathing air System manufacturers are Vacuum filtration equipment manufactured for medical use. Contaminants found in Vacuum lines include hospital waste and other biological fluids. Cleansweep Medical Vacuum Filters remove all these contaminants.

Operation of Breathing air systems

Trident Breathing air systems

Medical filter Manufacturers

Medical bacteria Filter

Medical Vaccum Filter

Trident Medical filter manufacturers are designed to remove the liquid, solid and bacterial contamination from the suction side of the vacuum pump and the potential biological infection of the surrounding environment. It Complies with HEALTH TECHNICAL MEMORANDUM 2022.

The filter elements and housings are designed for medical use and can be utilized in hospitals, pharmaceutical laboratories, dentist’s surgery and other critical areas.

These are Installed on suction side of vacuum pump to remove bacteria and prevent contamination to the pump and atmosphere.

Biological liquids are collected in a transparent drain flask, which can be easily removed for sterilization. The flask should be visually inspected daily and removed for cleaning and sterilization. The filter element must be replaced at least every6 months or when the pressure drop reaches 100 mbar.(ΔP gauge,pointer moves to Red)

The efficiency of the installed filter elements exceeds the 0.005% penetration specified in HTM 2022 for infectious disease units, when tested in accordance with BS 3928.

Trident Cleansweep Medical Vacuum Filters—High Performance Series are designed to remove the liquid, solid, and bacterial contamination from the suction side of the vacuum pump and the potential biological infection of the surrounding environment with low pressure drop. The filter elements and housings are designed for medical use and can be utilised in hospitals, pharmaceutical laboratories, dentist’s surgery, and other critical areas. They are installed on the suction side of the vacuum pump to remove bacteria medical bacteria filter and prevent contamination of the pump and atmosphere. Biological liquids are collected in a transparent drain flask, which can be easily removed for sterilisation. The flask should be visually checked daily and removed for cleaning and sterilisation. The medical filters element must be replaced at least every 6 months or when the pressure drop reaches 100 mbar towards the end of the red zone of the differential pressure indicator. The efficiency of the installed filter elements exceeds the 0.005% penetration specified in HTM 2022 for infectious disease units when tested in accordance with BS 3928. 

Medical Vaccum Filter

Operation of Breathing air systems

Vacuum from the system enters into the filter through inlet port. Vacuum free of impurities and contaminants is delivered by the filter through the outlet port. The head unit houses the vacuum inlet and outlet of the filter with the differential guage mounted on the top.

This gauge indicates the pressure drop across the filter. The gauge is provided with two dials for convenience. When there is a flow of compressed air through the filter, the needle of the gauge indicates the pressure drop qualitatively.

If the filter element within the Medical filter manufacturers is clean, the pressure drop across it is low, and the needle is in the green region. The impurities from incoming vacuum accumulate within the filter element, and the pressure drop increases. When the needle is in the red region, the pressure drop is high, and the filter element needs to be changed. To ensure that required filtration level can be met.

Biological fluids in the Vacuum, collects in the filter, along with oil, during operation. The oil and fluid are discharged periodically through the outlet. Biological fluids collects in the Drain flask is easily detached from the breathing air system by closing the Ball valve and it is kept into the autoclave, then it can be used again.

Medical Vacuum Filters
High Performance Series

Salient Features

Product Range

Model Item Code Pipe connections Flow rate at atmospheric pressure Housing Dimensions (mm) Spares Item Code
NPT BSP scfm n-l/min A B C Filter element kit Drain Drain
T250VP PFV13 PFV15 1” 30 850 114 399 70 AS946 AC249
T600VP PFV19 PFV21 1½” 40 1133 114 474 AS943
T851VP PFV20 PFV22 2” 115 3256 148 666 AS945
T1210VP PFV17 PFV23 2” 140 3964 148 736 AS949
T1810VP PFV18 PFV24 3” 265 7504 211 761 AS950
Correction factor
Absolute Vacuum mm Hg (abs) 750 369 242 178
in Hg (abs) 29.5 14.5 9.5 7.0
mbar (abs) 1000 492 322 238
psi (abs) 14.5 7.1 4.7 3.4
Correction factor - 1 2 3 4